316 Stainless Steel Dual Plate Flange Type Check Valve With Retainerless
TC8-1-CF8.CF8M
CF8.CF8M Flange retainerless dual check valve
CF8.CF8M - literally, "stainless steel" is the steel rusty hardly. Stainless steel is used where both the properties of steel and corrosion resistance are required.
Stainless Steel are devided into many serials. Most commonly are A351 CF8,A351 CF8M,A351 CF3M…etc.
Flange type retainerless type check valves are offered as standard on larger size valves where the lay length of the body permits installation of two nuts between the flanges. Flange type check valve is installed between two flanges using a separate set of bolts for each flange. This setup permits either side of the piping system to be disconnected without disturbing the other side. Flange Type Check Valve with two discs permits installation in a piping system in same manner as any conventional double flanged valve, i.e. studs and nuts per flange; this is one of the easiest connections to be installed or uninstalled from a pipeline. As Double flanged Type Check Valves are fastened to the pipe flanges, assembling or disassembling them is quick and easy. An important point to be mentioned about Double Flange types of end connections is that they are secured with several bolts. Flanged connections are the most common method of connecting valves, regardless of the pressure level (from low to high pressure levels) and valve size (from small to large valves). Flange dual plate check valves work automatically and it is not controlled by a person or any external control. Double flanged Type is offered as standard on larger size valves where the lay length of the body permits installation of two nuts between the flanges. Flange type valves are provided with thru-hole bolting in accordance with API 594, and if you have another standard demand, please send the inquiry to TVCCL. The Retainerless type is a type which body without pin retainer holes in the body. Retainerless type check valve use carrier and screw instead of retainer function to fix the pin. This design minimizes prospective leak paths through the valve body making it a preferable option for highly toxic, corrosive, or hazardous gas chemical processing applications. Retainerless valves are also suitable for high-temperature liquid, natural gas, steam service applications. Retainerless type check valve all inserts/parts are all the same as Dual plate check valve, except for using carrier and screw to replace the retainer. Simply, Dual plate check valve is drill four holes through the body of the check valve to facilitate installation of a hinge pin and stop pin, but Retainerless can be fixed by carrier and screw and is no need to drill the holes outside of valve’s body. Model: TC8 Wafer or Double Door Check Valves have no through holes. The Retainerless special to use in industry, especially offshore or onshore pipelines, there is a tremendous concern for fugitive emissions and potential environmental concerns. Retainerless check valve design also provides higher integrity on high pressure, ensuring no concerns about leakage.
Flange type valves are provided with thru-hole bolting in accordance with API 594.
Features
- Double flange design, install between pipe and flange by bolts and nuts, like dual plate wafer type check valve.
- Do not have any leakage problem on Body.
Specification
- Size: 12" ~ 60" (DN300 - DN1500)
- Pressure Rating For ASME: 125# ~ 2500# Suit For ASME / MSS / API Flange
- Pressure Rating For ISO: PN10 ~ PN40 Suit For ISO Flange
- Pressure Rating For JIS: 5K ~ 20K Suit For JIS Flange
- Material:WCB,CF8,CF8M,ALBC3,A8904A(MOQ)
- Designed in accordance with API 594
- End Connection: Wafer (TC8), Lugged (TC8-2, TC8-3)
- (Other flange connection please contact Taiwan Valves Centre Co., Ltd.)
- *Technical information is only for reference. Taiwan Valves Centre Co., Ltd. reserves the right to change without previous notice.
Applications
- Flange retainerless dual check valve is suitable for high temperature and high pressure environment, like Petrochemical, Refinery or power plant.
- Flange dual plate check valves with Retainerless have two plate in the body, work automatically and most are not controlled by a person or any external control.
- Double Flange check valve is designed to provide a cost-effective solution to your flow control and product shut-off requirements
- Dual plate flange-type valve used in many general applications such as in water distribution, water treatment, dams, power plants and in many other.
- A double flanged valve suited for heavy duty services such as shipbuilding and wastewater plants.
- Flange type check valve can be applied to Chemical, petrochemical industry.
- Dual flange type check valve suitable for Mineral-oil industry
- Double flange check valve used for Heating, air-conditioning, pipelines.
- Retainerless dual check valve is suitable for high temperature and high pressure environment, like Petrochemical, Refinery or power plant.
- Use for any industry concerned with fire hazards or environmental safety
- Suitable for use in clean, dirty and sea water applications.
- Also use for gases like Chlorine, Hydrogen, Nitrogen, Carbon Dioxide (Co ), Oxygen etc.
- Retainerless type check valve can be installed in heating air-conditioning pipe lines.
- Installed in hydrocarbon and chemical processing.
- Retainerless Duo check Valve also can be used in steam/vapor applications.
- Retainerless dual check valve is a preferable option for highly toxic, corrosive, or hazardous gas chemical processing applications.
- Applied in Iron and steel industry.
More Knowledge about TVCCL valve:
TVCCL Retainerless wafer check valve body features a single cast body without penetration through the body wall, eliminating the possibility of outside leakage; making it a preferable option for High-temperature work environment. Under the normal using situation, TVCCL guarantee retainerless type valve does not have any leakage problem on Body. Dual plate check valve with retainerless are available in 4 basic types: Wafer, Lug, Solid Lug, Flanged end, and in an extensive range of sizes, pressure classes and materials.
TVCCL check valve made of selected materials, each valve we made can offer the material certificate which according to BS EN 10204 3.1. Under the normal using situation, we can guarantee the TVCCL valve is more durable than the other manufacturers. And the performance is more reliable and practical. Using check valve under normal situation all can achieve the non-return effect. However, if the pipeline installation distance is less than 6~8 times the size of the valve, the life of the check valve may be shortened or the valve body and parts may be damaged.
- Related Products
Dual Plate Wafer Type Check Valve
TC0
The dual plate wafer type check valve are manufactured in accordance with API, ASTM, ANSI,...
DetailsDual Plate Wafer Type Check Valve With Retainerless
TC8
The dual disc check valve with its compact wafer design and low cost have made it a popular...
DetailsDual Plate Lug Type Check Valve With Retainerless
TC8-2
Dual plate lug type with retainerless check valve’s body features a single cast body without...
DetailsDual Plate Full Lug Type Check Valve With Retainerless
TC8-3
Full lug type dual Plate Check valve with retainerless series are more and more popular because...
Details- Files Download
Dual Plate Wafer Style Check Valve Installation and Maintenance Instructions
Installation and Maintenance Instructions for dual plate check valve
Download- FAQ
Q.What Is Check Valve?
TVCCL Check Valve is a dual plate check valve that conforms to API 594. TVCCL is known as one of the leading manufacturers of Valve in Taiwan since we established.A...
Q. How Do Install Double Disc Check Valve In Pipe?
Taiwan Valve Centre Co.,Ltd. is the professional dual check valve manufacturers in the Taiwan. This information concerning the installation and operation...
Q. What Kind Of Material TVCCL Stock For Dual Check Valve?
Materials Stocked for Dual Plate Check Valve by TVCCLTVCCL, a pioneer in valve manufacturing, has been at the forefront of the industry since 1998. Our expertise...
316 Stainless Steel Dual Plate Flange Type Check Valve With Retainerless - CF8.CF8M Flange retainerless dual check valve | Made in Taiwan Dual Plate Check Valves Manufacturer | Taiwan Valve Centre Co., Ltd.
Located in Taiwan since 1998, Taiwan Valve Centre Co., Ltd. has been a dual plate check valve manufacturer with all the valves sold to 1,500 clients in 80 countries worldwide. Their main valve products, including 316 Stainless Steel Dual Plate Flange Type Check Valve With Retainerless, dual plate check valves, dual plate full lining type, retainerless check valves, bypass check valves, short and long wafer check valves and spring wafer type for industries, such as oil, shipbuilding, seawater desalination, cooling system and nuclear.
TVCCL has a competitive pricing, reliable quality product and excellent after-sales support, well-down packing. We have received good reputation as being a well-known supplier in supplying reliable quality and competitive price check valves from customers. 20 years of experiences in producing dual plate check valve, excellent after-sales support, OEM / ODM, oil industry, shipbuilding, seawater desalination, cooling system, nuclear industry.
TVCCL, TAIWAN VALVE has been offering customers high-quality and durable industrial check valves for any applications since 1998, both with advanced technology and 25 years of experience, TVCCL, TAIWAN VALVE ensures each customer's demands are met.